Sectional cast-iron solid-fuel boiler range for water-based central heating systems using coal or firewood.
The Pegas range is intended for buildings that require an independent solid-fuel heat source. The sectional design allows the boiler output and water volume to increase with the number of cast-iron sections.
Model selection must be based on building heat loss, chimney parameters and the hydraulic protection of the heating system.
| Parameter | Value |
|---|---|
| Fuel | coal or firewood |
| Heat exchanger | sectional cast iron |
| Output range of listed versions | 20.9-39.5 kW |
| Maximum operating temperature | 95°C |
| Flue outlet of listed versions | 162 mm |
| Model | Output, kW | Dimensions, mm | Water volume, l | Flue, mm | Weight, kg | Sections |
|---|---|---|---|---|---|---|
| Pegas 4 | 20.9 | 455 × 470 × 1078 | 27 | 162 | 210 | 4 |
| Pegas 5 | 23.6 | 555 × 470 × 1078 | 31 | 162 | 245 | 5 |
| Pegas 6 | 30.2 | 655 × 470 × 1078 | 35 | 162 | 280 | 6 |
| Pegas 7 | 34.9 | 755 × 470 × 1078 | 39 | 162 | 315 | 7 |
| Pegas 8 | 39.5 | 855 × 470 × 1078 | 43 | 162 | 350 | 8 |
The table reproduces the model-specific values stored in the Hi-Therm product data for Pegas 4-8. Installation requires a correctly sized chimney and heating-system safety equipment.